IT-RU-HVJ
ES
3919109900
Availability: | |
---|---|
Quantity: | |
High Voltage Jacketing Rubber Insulation Tapes
SPECIFICATIONS | |||
MATERIAL: | ETHYLENE PROPYLENE RUBBER (EPR) | ||
STANDARD: | UL | ||
COLOUR: | BLACK (STANDARD) | ||
INSULATION: | UP TO 138KV | ||
FEATURE: | SELF-AMALGAMATING( IT FUSES QUICKLY YIELDING A VOID-FREE, ELECTRICALLY STABILIZED JACKET) EXCELLENT UV, CORONA AND OZONE RESISTANCE SUPERIOR ELECTRICAL PROPERTIES OUTSTANDING MOISTURE, CORROSION, CHEMICAL AND CABLE IMP REGNANT RESISTANCE. | ||
APPLICATION: | FOR INSULATING AND JACKETING OF SPLICES ON POWER CABLES UP TO 138 KV. ALSO WIDELY USED FOR BUILDING STRESS CONES AND JACKING OF TERMINATIONS ON POWER CABLE UP TO 35KV. |
PROPERTY | VALUE | UNIT | TEST METHOD |
TOTAL THICKNESS | 0.5 | mm | ASTM-D-4325 |
TENSILE STRENGTH | 250 | Psi | ASTM-D-4325 |
ELONGATION AT BREAK | 700 | % | ASTM-D-4325 |
CONTINUOUS OPERATING TEMP. | 90 | °C | ASTM-D-4325 |
EMERGENCY OVERLOAD TEMP. | 130 | °C | ASTM-D-4325 |
WATER ABSORPTION | 0.02 | % | ASTM-D-570 |
OZONE RESISTANCE | PASS | - | ASTM-D-4325 |
UV RESISTANCE | PASS | - | ASTM-D-4325 |
ELECTRICAL PROPERTY | |||
DIELECTRIC STRENGTH | 69 | K v/mm | ASTM-D-4325 |
DIELECTRIC CONSTANT | |||
24h @ 23°C | 2.6 | - | ASTM-D-4325 |
168h @ 70°C | 2.6 | - | ASTM-D-4325 |
DIELECTRIC CONSTANT | |||
24h @ 23°C | 0.001 | - | ASTM-D-4325 |
168h @ 70°C | 0.005 | - | ASTM-D-4325 |
VOLUME RESISTIVITY | 10^16 | Ohm-cm | ASTM-D-4325 |
EASE CODE | THICKNESS | WIDTH | LENGTH | CORE |
mm | mm | m | mm | |
IT-RU-HVJ-0.5/19/9.1 | 0.5 | 19 | 9.1 | 38 |
IT-RU-HVJ-0.5/25/9.1 | 0.5 | 25 | 9.1 | 38 |
IT-RU-HVJ-0.5/38/9.1 | 0.5 | 38 | 9.1 | 38 |
IT-RU-HVJ-0.5/50/9.1 | 0.5 | 50 | 9.1 | 38 |
High Voltage Jacketing Rubber Insulation Tapes
SPECIFICATIONS | |||
MATERIAL: | ETHYLENE PROPYLENE RUBBER (EPR) | ||
STANDARD: | UL | ||
COLOUR: | BLACK (STANDARD) | ||
INSULATION: | UP TO 138KV | ||
FEATURE: | SELF-AMALGAMATING( IT FUSES QUICKLY YIELDING A VOID-FREE, ELECTRICALLY STABILIZED JACKET) EXCELLENT UV, CORONA AND OZONE RESISTANCE SUPERIOR ELECTRICAL PROPERTIES OUTSTANDING MOISTURE, CORROSION, CHEMICAL AND CABLE IMP REGNANT RESISTANCE. | ||
APPLICATION: | FOR INSULATING AND JACKETING OF SPLICES ON POWER CABLES UP TO 138 KV. ALSO WIDELY USED FOR BUILDING STRESS CONES AND JACKING OF TERMINATIONS ON POWER CABLE UP TO 35KV. |
PROPERTY | VALUE | UNIT | TEST METHOD |
TOTAL THICKNESS | 0.5 | mm | ASTM-D-4325 |
TENSILE STRENGTH | 250 | Psi | ASTM-D-4325 |
ELONGATION AT BREAK | 700 | % | ASTM-D-4325 |
CONTINUOUS OPERATING TEMP. | 90 | °C | ASTM-D-4325 |
EMERGENCY OVERLOAD TEMP. | 130 | °C | ASTM-D-4325 |
WATER ABSORPTION | 0.02 | % | ASTM-D-570 |
OZONE RESISTANCE | PASS | - | ASTM-D-4325 |
UV RESISTANCE | PASS | - | ASTM-D-4325 |
ELECTRICAL PROPERTY | |||
DIELECTRIC STRENGTH | 69 | K v/mm | ASTM-D-4325 |
DIELECTRIC CONSTANT | |||
24h @ 23°C | 2.6 | - | ASTM-D-4325 |
168h @ 70°C | 2.6 | - | ASTM-D-4325 |
DIELECTRIC CONSTANT | |||
24h @ 23°C | 0.001 | - | ASTM-D-4325 |
168h @ 70°C | 0.005 | - | ASTM-D-4325 |
VOLUME RESISTIVITY | 10^16 | Ohm-cm | ASTM-D-4325 |
EASE CODE | THICKNESS | WIDTH | LENGTH | CORE |
mm | mm | m | mm | |
IT-RU-HVJ-0.5/19/9.1 | 0.5 | 19 | 9.1 | 38 |
IT-RU-HVJ-0.5/25/9.1 | 0.5 | 25 | 9.1 | 38 |
IT-RU-HVJ-0.5/38/9.1 | 0.5 | 38 | 9.1 | 38 |
IT-RU-HVJ-0.5/50/9.1 | 0.5 | 50 | 9.1 | 38 |